MOOSIB 12V 50Ah 610Wh Sodium lon Starting Battery
Features of Sodium ion Battery
- Longer Cycle Life:4X longer life,20 times longer cycle life than lead-acid batteries,reducing user costs.
- Lighter Weight:Only 40%lighter than comparable lead-acid batteries
- Higher Power:Delivers over 500-amps of starting power,over 50,000 starts,and over 2,000 charge cycles,meaning:it has 2X more power and 10X more starts
- Wider Temperature Range:-40℃~+80℃
- Superior Safety:The electrochemical performance of sodium-ion batteries is relatively stable,and it is safer than lithium-ion batteries in use. Moreover sodium batteries can work normally in the temperature range of 40°C to 80°C,and the capacity retention rate is close to 90%in the environment of-20°C,and the high and low temperature performance is better than that of other secondary batteries.
description2
Application
Car starting /Car rescue
description2
Warranty
We provide five-year warranty for all our batteries.And our five-year battery warranty includes the following privileges when used correctly in accordance with the manual instructions. We'll assist to analyze customer's problem within 24 hours,and help to solve problem,restore battery usage,and introduce the optimal use method.
description2
Battery Dimensions:LxWxH=9.6x6.92x7.75
Installation Tips
Premise of Installation:The battery size or model number should be consistent.
- nstallation Steps:
-
Step 1:After unpacking,check the battery voltage,the voltage should be greater 12.8V;Step 2:After the battery voltage is normal,connect the red connector of car to the positive copper column and the black connector to the negative copper column;Step 3:After the vehicle starts normally,secure the battery;Step 4:After the above steps are installed,the vehicle still cannot be started, contact the deale.
description2
Warning &Tips
1.Pay attention to the output voltage of the vehicle engine after starting≥13.5V,≤15.2V;
2.Do not use batteries in series.Carrescue can be used in parallel connection with lead-acid batter;
3.Do notreversely connect positive and negative of the battery,reverse connection will cause short circuit;
4.Do notinstall electronic equipment without authorization,it will affect the battery life.Do not disassemble or modify the battery;
5.If the vehicle is in normal condition and will not be used for a short period of time it need to start the vehicle every 15 days for 15 minutes. If it is not used for a long time,it is recommended to disconnect the negative pole of the power supply;
6.Itis strictly forbidden to immerse the battery in sea water or throw it into fire. It is strictly prohibited to use chargers that do not meet the charging requirements.
description2
Battery Specification
Solar panels fast charge, enjoy endless green energy use electricity like a home.
description2
Mode | 2.21 | ||
---|---|---|---|
Nominal Voltage | 12.2V | Nominal Capacity | 50At |
Nominal Energy | 610Wt | Standard Charge Voltag | 16.0V(13.5Min~15.5V Max.) |
Tion Life | >50,000 s | Discharge Cut-off Voltage | 8.0~9.5V |
Allowed Max.Charge Curren | 80A | Max.Discharge Curren | 80A |
Peak Discharge Current @10S | 200A | Peak Discharge Current @3S | 480A |
CCA | 480 CCA | Tem | Charge temperature:-40℃~+50℃/Disc -40℃~+70 |
BMS -Battery Management System
description2
TEMS | PARAMETER | ||
---|---|---|---|
Dver charge detection voltage | 3.95V*4S(Delay 0.5~2S | Over charge release voltage | 3.7V*4S(Delay 0.5~2S) |
Over discharge detection voltage | 1.6V*4S(Delay 0.5~2S | Ovor discharge release Voltage | 2.3V*4S(Deley 0.5~2S |
Max.Charge Current | 80A | Max.Discharge Current | 80A |
Peak Discharge Current | 400~600A@3S | ||
State of Charge(soc)
Battery capacity can be estimated by voltage. Due to the slight difference inthe voltage of each battery, the following parameters are for reference only.Need to test voltage & load at rest (zero current)15 minutes afterdisconnecting the charger.
recommendlow voltage disconnect voltage: 8.8V
description2
Capacity |
Voltage
Capacity
|
||
---|---|---|---|
100% | 16.0V | 99% | 15.6V |
90% | 15.6V | 80% | 14.8V |
70% | 14.6V | 60% | 14.0V |
50% | 13.4V | 40% | 12.8V |
30% | 12.2V | 20% | 11.8V |
10% | 11.4V | 10.4V | 10.4V |
1% | 8.8V |
10.4V | 8.0V |
How To Activate The Battery
If the BMS has cut-off the battery protection, you need to cut off the load on thebattery and leave the battery for 30minutes. Then the battery will automaticallyreturn to normal voltage and can be used when fully charged.
If the battery doesn't recover on its own and the voltage is too low to keep chargeyou can activate it in two ways:
1.Use a charger with 0V charging function (can charge the battery from 0V) tocharge the battery.After fully charged ,the battery can be used normally.
2. Use another 12V lithium battery in parallel with the battery to activate the batteryfor one minute or use a lead-acid battery with a voltage of >12V and <16V toactivate the battery in parallel. Finally, fully charge the battery for normal use
description2